PR 12-1 V1

Hydraulic tube 12x1 1.4301

Hydraulic tube 12x1 1.4301

Detalji o proizvodu za

PR 12-1 V1

Ø d1
12 mm
S
1 mm
Specific load I
186 bar
Specific load III
140 bar
Ø d2
10 mm
AD tolerance +/-
0.08 mm
ID tolerance +/-
0.15 mm
Sva svojstva

Svojstva

Construction type
  • precision steel tube, seamless, (cold-drawn), metric 
Construction type addition
  • CFA = bright annealed (annealed; metallically bright) 
Design
  • metric 
Material
  • stainless steel X5CrNi18-10 (1.4301) 
Standard
  • DIN EN 10216-5 
Tube length
  • 5 to 7 metres*. 
Customs tariff number
  • 73044100 
Sva svojstva

Opis proizvoda

Napomene
The pressure figures are based on straight tubes.
The appropriate wall thickness needs to be calculated for tubes with bends as stipulated in DIN EN 13480-4.
*Stainless steel tubes are supplied in manufactured lengths according to EN 10216-5. In terms of production, these are usually 6 meters (+/- 1m). Order quantities are rounded to the nearest possible total length, without cutting.
Opis
The stainless steel pipes made of materials 1.4301 (V1), 1.4541 (V2) and 1.4571 (V4) are supplied in CFA condition (bright annealed) as standard. This condition offers very good bendability and is the established standard in the hydraulics sector, particularly for the installation of pipelines.
Dodatne informacije
Calculation analog DIN 2413
Specific load I: static (up to 120 °C)
Specific load III: dynamic (up to 120°C)
Working stroke= P bar
Strength parameter: K 218 [N/mm²]
Safety coefficient: S 1.5
Fatigue strength: σSch/D 175 [N/mm²]
Tolerances: DIN EN 10305-1 (diameter-/wall thickness indication)
Elastic strength to DIN DIN 10216-5 Rp 1.0 to 50°C
The fatigue strength value was reduced in relation to the strength parameter by 1.4571.
Napomena o narudžbi
Other delivery conditions, such as CFD, are available on request and must be specified separately.

Product variants

44 Results
Prikaži crtež s dimenzijama
Oznaka
Ø d1 (mm)
S (mm)
Specific load I (bar)
Specific load III (bar)

Shows 10 of 44

Column selection

Ø d1 (mm)
S (mm)
Specific load I (bar)
Specific load III (bar)
Ø d2 (mm)
AD tolerance +/- (mm)
ID tolerance +/- (mm)