HK DLEHM 3C X 24DC

3/2-Wegesitzventil NG 6, 24 VDC.
Type
3/2 
Flow rate max.
30 l/min
Design
power-off open 
Download PDF
Registrirajte se sada za mogućnost pristupa našoj internetskoj trgovini.

Register now and access our complete product range and many exclusive services.

Product details for

HK DLEHM 3C X 24DC

Type
3/2
Flow rate max.
30 l/min
Design
power-off open

Characteristics

Connection
  • ISO/Cetop 03 size 6 
Flow rate
  • max. 30 l/min (note characteristic curves) 
Max. working pressure
  • P, A, B: max. 350 bar (HK DLEH); max. 315 bar (HK DLEHM) T: max. 210 bar 
Mounting
  • 4 pcs. hexagon socket screw M 5 x 50 12.9 
  • screw set HK M5 50 for 1 basic valve. In vertical stacking applications with intermediate plates, the use of the appropriate longer screws are required. 
Customs tariff number
  • 84812010 
All characteristics

Opis proizvoda

Notes
The O-rings (NBR 70 Shore A) for the valve port can be ordered as spare part separately under the following article number: 4 pieces OR8.73-1.78
The valves of type HK DLEH can be equipped with a plug-in non-return valve in port P (see accessories)
Description
2- or 3- way seat valves with 2 switching positions.
Solenoids and all moving parts switch internally in oil.
Solenoid coil 24 VDC with emergency manual override.
Delivery scope
Without plug
With coil, 24 V DC

Product variants

6 Results
Show dimensional drawing
Identifier
Type
Flow rate max. (l/min)
Design

Column selection

Type
Flow rate max. (l/min)
Design