Type
4/2
Nominal voltage/ current type
110 V AC
Overlap
negative (open)
Register now to get access to our online shop
Register now and access our complete product range and many exclusive services.
Product details for
HK DG4V5 0B VM U 110AC
Type
4/2
Nominal voltage/ current type
110 V AC
Overlap
negative (open)
Piston type
0B [PB/AT]-[ABPT]
Design material
spring return
All characteristics
Characteristics
Radni tlak
- P, A, B: maks. 315 bara / T: maks. 160 bara (VDC) / T: maks. 120 bara (V AC)
Izvedba
- 4/2-smjerni ventil ili 4/3-smjerni ventil
- s ručnim aktiviranjem u nuždi
Priključak
- ISO/Cetop 05 NV10
Volumenska struja
- maks. 120 l/min (obratite pozornost na krivulje)
Pričvršćenje
- 4 kom. imbus vijaka M6x40 12,9
- screw set HK M6 40 for 1 basic valve. In vertical stacking applications with intermediate plates, the use of the appropriate longer screws are required.
Razred zaštite
- IP 65
Customs tariff number
- 84812010
All characteristics
Product description
Notes
Description
Ordering information
Delivery scope
Product variants
9 Results
Search
Show dimensional drawing
Identifier
4/2
110 V AC
negative (open)
0B [PB/AT]-[ABPT]
4/2
110 V AC
positive (closed)
6B [PB/AT]-[ABT/P]
4/2
230 V AC 50 Hz
positive (closed)
6B [PB/AT]-[ABT/P]
4/2
230 V AC 50 Hz
positive (closed)
22A [PB/A/T]-[PA/B/T]
4/3
12 V DC
negative (open)
0CJ [PB/AT]-[ABPT]-[PA/BT]
4/3
110 V AC
negative (open)
0C [PB/AT]-[ABPT]-[PA/BT]
4/3
12 V DC
positive (closed)
6CJ [PB/AT]-[ABT/P]-[PA/BT]
4/2
12 V DC
positive (closed)
2NJ [PB/AT]-[PA/BT]
4/2
24 V DC
positive (closed)
2NJ [PB/AT]-[PA/BT]
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]
Column selection
Type
Nominal voltage/ current type
Overlap
Piston type
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]