HK 71 A4 B35 2-4 IE2

E-Motor 230/400V 0,25kW 1380U B35 IE2
P 50 Hz
0.25 kW
n 50 Hz
1,380 r/min
P 60 Hz
0.3 kW
Download PDF
Registrirajte se sada za mogućnost pristupa našoj internetskoj trgovini.

Register now and access our complete product range and many exclusive services.

Product details for

HK 71 A4 B35 2-4 IE2

P 50 Hz
0.25 kW
n 50 Hz
1,380 r/min
P 60 Hz
0.3 kW
n 60 Hz
1,656 r/min
LF 50 Hz
0.74
Factor IA / IN
5.2
η (IE2) %
67.3
A
112 mm
B
215 mm
C
183 mm
H
71 mm
I 50 Hz
0.72 A
Ø D shaft
14 mm
Ø E
110 mm
Ø F
160 mm
All characteristics

Characteristics

Ambient temperature
  • -20 °C to +40 °C 
Protection IP
  • IP 55 
Material
  • housing: aluminium 
Design
  • Type B3/B5 
  • removable feet 
Customs tariff number
  • 85015220 
All characteristics

Opis proizvoda

Description
Self-cooling squirrel-cage energy-saving motors.
High efficiency IE2 - IEC60034-30:2009.
Rated voltage 230/400 V 50 Hz, 460 V 60 Hz.
4-pin.
Voltage tolerance ±5 %.

Product variants

3 Results
Show dimensional drawing
Identifier
P 50 Hz (kW)
n 50 Hz (r/min)
P 60 Hz (kW)
n 60 Hz (r/min)
P 60 Hz = nominal output at 400 V/60 Hz
n 50 Hz = nominal speed at 400 V/50 Hz
n 60 Hz = nominal speed at 400 V/60 Hz
I 50 Hz = nominal current at 400 V/50 Hz
LF 50 Hz = cos phi power factor at 50 Hz
P 50 Hz = nominal output at 400 V/50 Hz
η (IE2) = efficiency to IE2 in % (at full load)
Factor IA / IN = start-up current IA / Nominal current IN

Column selection

P 50 Hz (kW)
n 50 Hz (r/min)
P 60 Hz (kW)
n 60 Hz (r/min)
LF 50 Hz
Factor IA / IN
η (IE2) %
A (mm)
B (mm)
C (mm)
H (mm)
I 50 Hz (A)
Ø D shaft (mm)
Ø E (mm)
Ø F (mm)
P 60 Hz = nominal output at 400 V/60 Hz
n 50 Hz = nominal speed at 400 V/50 Hz
n 60 Hz = nominal speed at 400 V/60 Hz
I 50 Hz = nominal current at 400 V/50 Hz
LF 50 Hz = cos phi power factor at 50 Hz
P 50 Hz = nominal output at 400 V/50 Hz
η (IE2) = efficiency to IE2 in % (at full load)
Factor IA / IN = start-up current IA / Nominal current IN